The
stator winding conductors are insulated by ‘F’ class epoxy based mica
insulation. Overhang conductors of stator winding are supported on stator
casing by fiber glass ring and fiber glass blocks. Conductors at overhang are
tied with the fiber glass ring by polyester cord. Near the exit point of the
conductor from core, one epoxy putty ring was made to reduce overhang conductor
vibration. Top and side ripple spring has been provided in the slot to further
reduce conductor vibration.